Purpose: for Electricity and Communication
Diameter (mm) |
The Numbers of Wire to Construct The Strand/ Standard Diameter/mm |
Cross-sectional Area (mm²) |
The Tensile Load of Steel Wire Strand |
Approximate Unit Weight kg/m |
|||||
1230
N/mm² (125 kgf/mm²) |
880
N/mm² (90 kgf/mm²) |
690
N/mm² (70 kgf/mm²) |
|||||||
kN | {tf} | kN | {tf} | kN | {tf} | ||||
3.0 | 7/1.00 | 5.50 | 6.19 | {0.631} | 4.48 | {0.457} | 3.47 | {0.354} | 43.5 |
3.6 | 7/1.20 | 7.92 | 8.90 | {0.908} | 6.44 | {0.657} | 4.99 | {0.354} | 62.7 |
4.2 | 7/1.40 | 10.8 | 12.2 | {1.24} | 8.78 | {0.895} | 6.83 | {0.509} | 85.3 |
4.8 | 7/1.60 | 14.1 | 15.9 | {1.62} | 11.5 | {1.17} | 8.90 | {0.908} | 111 |
5.4 | 7/1.80 | 17.8 | 20.1 | {2.05} | 14.4 | {1.47} | 11.3 | {1.15} | 141 |
6.0 | 7/2.00 | 22.0 | 24.8 | {2.53} | 17.8 | {1.82} | 13.9 | {1.42} | 174 |
6.9 | 7/2.30 | 29.1 | 32.8 | {3.34} | 23.6 | {2.41} | 18.3 | {1.87} | 230 |
7.8 | 7/2.60 | 27.2 | 42.0 | {4.28} | 30.2 | {3.83} | 23.5 | {2.40} | 294 |
8.7 | 7/2.90 | 46.2 | 52.2 | {5.32} | 37.6 | {3.83} | 29.2 | {2.98} | 366 |
9.6 | 7/3.20 | 56.3 | 63.7 | {6.50} | 45.7 | {4.66} | 35.6 | {3.63} | 446 |
10.5 | 7/3.50 | 67.3 | 75.8 | {7.73} | 54.7 | {5.58} | 42.5 | {4.33} | 533 |
11.4 | 7/3.80 | 79.3 | 89.6 | {9.14} | 64.4 | {6.57} | 50.1 | {5.11} | 628 |
12.0 | 7/4.00 | 88.0 | 99.1 | {10.1} | 71.4 | {7.28} | 55.6 | {5.67} | 696 |